[2026-10-29T18:41:44.451Z] [info] SUT version: v1.0.0 [2026-10-29T18:41:44.451Z] [info] Connecting to USB Configuration Link [2026-10-29T18:41:44.453Z] [info] Successfully established connection with the USB Configuration Link (USB device /dev/ttyUSB0) [2026-10-29T18:41:44.453Z] [info] Connected to USB Configuration Link [2026-10-29T18:41:44.453Z] [info] Starting wearable start-up sequence [2026-10-29T18:41:44.475Z] [info] Wearable Unique Device ID: 0447323532363232004A0036 [2026-10-29T18:41:44.483Z] [info] Wearable start-up checks were completed in less than 10 seconds [2026-10-29T18:41:44.483Z] [info] STARTUP_CHECKS_DONE_CP_STATE = completed [2026-10-29T18:41:44.483Z] [info] STARTUP_CHECKS_TIMEOUT_CP_STATE = allocated time not reached [2026-10-29T18:41:44.483Z] [info] BANK1_INVALID_CP_STATE = valid [2026-10-29T18:41:44.483Z] [info] BANK2_INVALID_CP_STATE = valid [2026-10-29T18:41:44.483Z] [info] RUN_BANK_CP_STATE = Bank 1 [2026-10-29T18:41:44.483Z] [info] FW_NOT_COMP_STATE = compatible [2026-10-29T18:41:44.483Z] [info] WPT_INVALID_CP_STATE = in allowed range [2026-10-29T18:41:44.483Z] [info] RFON_INVALID_CP_STATE = valid [2026-10-29T18:41:44.483Z] [info] ENABLE_RFON_INVALID_CP_STATE = valid [2026-10-29T18:41:44.494Z] [info] Current Firmware Version and Hardware Identifiers: [2026-10-29T18:41:44.494Z] [info] Bank number = 0 [2026-10-29T18:41:44.494Z] [info] FW Version = 1.1.0 [2026-10-29T18:41:44.494Z] [info] FW Product Identifier = 5344 [2026-10-29T18:41:44.494Z] [info] FW Subsystem Identifier = 4350 [2026-10-29T18:41:44.494Z] [info] FW Compatibility version = 01 [2026-10-29T18:41:44.494Z] [info] MCU Product Identifier = 5344 [2026-10-29T18:41:44.494Z] [info] MCU Subsystem Identifier = 4350 [2026-10-29T18:41:44.494Z] [info] MCU HW version = 01 [2026-10-29T18:41:44.511Z] [info] Wearable firmware build identity: 1.1.0-dev+b1510.g5ba050d (bank 0, 17988 bytes, CRC32 0x8A006F45) [2026-10-29T18:41:44.511Z] [info] Wearable start-up sequence completed [2026-10-29T18:41:44.511Z] [info] Starting implant start-up sequence [2026-10-29T18:41:44.518Z] [info] Implant powered-on [2026-10-29T18:41:45.545Z] [info] Implant start-up checks were completed in less than 10 seconds [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_STARTUP_CHECKS_DONE = completed [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_BANK1_INVALID = valid [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_BANK2_INVALID = valid [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_RUNNING_BANK = Bank 1 [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_BANKS_DIFF = identical [2026-10-29T18:41:45.545Z] [info] IMP_FW_STATE_NOT_COMP_WITH_HW = compatible [2026-10-29T18:41:45.545Z] [info] IMP_FPGA_STATE_STARTUP_CHECKS_DONE = completed [2026-10-29T18:41:45.545Z] [info] IMP_FPGA_STATE_BITSTREAM_INVALID = valid [2026-10-29T18:41:45.545Z] [info] IMP_SENSORS_STATE_STARTUP_CHECKS_DONE = completed [2026-10-29T18:41:45.545Z] [info] IMP_SENSORS_STATE_IMPLAUSIBLE_TEMPERATURE = implausible [2026-10-29T18:41:45.621Z] [info] Implant Unique HW ID: 0747373435333434002E0036 [2026-10-29T18:41:45.731Z] [info] Implant HW Revision ID FW: 5344494D02. Implant HW Revision ID FACTORY: 5344494D02 [2026-10-29T18:41:45.731Z] [error] Implant start-up sequence failed because at least one of the MCUs Firmware states is invalid [2026-10-29T18:41:46.007Z] [info] Implant firmware build identity: 1.1.0-dev.ablapp-1502-keepalive-7s+b1413.gb44b676 (bank 0, 21572 bytes, CRC32 0x08E3E045) [2026-10-29T18:41:46.074Z] [info] Implant FPGA bitstream: 135180 bytes, CRC32 0xA50ED517 [2026-10-29T18:41:46.074Z] [info] Implant start-up sequence completed [2026-10-29T18:41:46.074Z] [info] Starting implant update sequence [2026-10-29T18:41:46.128Z] [info] Current firmware: v1.1.0, active bank: 0 [2026-10-29T18:41:46.128Z] [info] Target firmware CRC: 0x08E3E045 [2026-10-29T18:41:46.220Z] [info] Bank 1 has target firmware: yes [2026-10-29T18:41:46.332Z] [info] Rebooting to switch to bank 1 [2026-10-29T18:41:51.884Z] [info] Current firmware: v1.1.0, active bank: 1 [2026-10-29T18:41:52.097Z] [info] Bank 1 firmware build identity: 1.1.0-dev.ablapp-1502-keepalive-7s+b1413.gb44b676 (bank 1, 21572 bytes, CRC32 0x08E3E045) [2026-10-29T18:41:52.162Z] [info] Bank 0 has target firmware: yes [2026-10-29T18:41:52.273Z] [info] Rebooting to switch to bank 0 [2026-10-29T18:41:57.824Z] [info] Current firmware: v1.1.0, active bank: 0 [2026-10-29T18:41:58.038Z] [info] Bank 0 firmware build identity: 1.1.0-dev.ablapp-1502-keepalive-7s+b1413.gb44b676 (bank 0, 21572 bytes, CRC32 0x08E3E045) [2026-10-29T18:41:58.038Z] [info] Both banks are up-to-date [2026-10-29T18:41:58.038Z] [info] Implant update sequence completed [2026-10-29T18:41:58.038Z] [info] SUT completed successfully